Home›Repair guides›Generac›Checking Gas Line Connections

Generac — Checking Gas Line Connections

Installation · Fuel System

From a Generac service manual — check it applies to your exact model before use.

Applies to: Generac 7.5 kW PowerPact

Procedure

  1. Remove top lid and rear panel
  2. Check for leaks with non-corrosive gas leak detection fluid at all connection points
  3. Close gas supply valve
  4. Remove top gas pressure test port from regulator, install manometer
  5. Open gas supply valve and verify pressure is within specified values
  6. Close gas valve when completed
  7. Reinstall rear access panel and top lid

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • NG: 5–7 in water column (9–13mm mercury)
  • LP: 10–12 in water column (19–22mm mercury)

Full service-parts list: Generac 7.5 kW PowerPact →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.