Home›Repair guides›Generac›Checking and Adjusting Valve Clearance

Generac — Checking and Adjusting Valve Clearance

Adjustments · valve train

From a Generac owner's manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Contact Dealer if uncomfortable performing this procedure

Procedure

  1. Cool the engine before checking
  2. Remove spark plug wire and spark plug
  3. Rotate flywheel nut clockwise to bring piston to TDC on compression stroke
  4. At 60-80°F, remove valve cover (4 screws)
  5. Loosen rocker jam nut, turn pivot ball stud while checking clearance with feeler gauge
  6. Set intake to 0.005-0.007 in, exhaust to 0.007-0.009 in
  7. Tighten jam nut to 70-106 in/lbs holding pivot stud
  8. Recheck clearance after tightening
  9. Install new valve cover gasket and reattach cover
  10. Reinstall spark plug and wire

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake 0.005-0.007 in (0.13-0.17mm)
  • Exhaust 0.007-0.009 in (0.18-0.22mm)
  • Jam nut torque 70-106 KuduParts $44.00 in/lbs

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.