Home›Repair guides›Generac›Check/Adjust Valves

Generac — Check/Adjust Valves

Adjustments · Valve train

From a Generac service manual covering: Craftsman 2200i C0010020, Craftsman 3000i C0010030, GP2200, GP3000i, GP3500iO, IQ3500, PRO-3000i INV3000DMN, Premier 2200i INV2200DMN, iQ2000, iQ3500, iX 1600, iX 2000…. Check it applies to your exact model before use.

Applies to: Generac GP3000i, Generac GP3500iO, Generac IQ3500, Generac iX 1600, Generac iX 2000

Procedure

  1. Verify the piston is at top dead center (TDC) of its compression stroke (both valves closed).
  2. Remove four (4) screws from rocker cover.
  3. Remove rocker cover and rocker cover gasket.
  4. Loosen rocker arm jam nut. Turn adjustment screw in to decrease clearance or out to increase clearance.
  5. Hold socket steady and tighten lock nut to specification; check clearance and make minor adjustments.
  6. After tightening jam nut, recheck valve clearance to make sure it did not change.
  7. Install rocker cover, gasket and four screws; tighten to specifications.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • GP3000i/GP3500io/IQ3500: 0.004-0.006 in (0.10-0.15 mm)
  • iQ and iX: 0.004 ± 0.001 in (0.10 ± 0.02 mm)

Full service-parts list: Generac GP3000i →, Generac GP3500iO →, Generac IQ3500 →, Generac iX 1600 →, Generac iX 2000 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.