Home›Repair guides›Generac›Battery Maintenance

Generac — Battery Maintenance

Maintenance

From a Generac owner's manual — check it applies to your exact model before use.

Browse Generac generators & specs →

Before you start

  • Disconnect negative battery cable first
  • Do not use tap water for battery
  • Remove jewelry and use insulated tools

Procedure

  1. Lift the lid and press the OFF button to shut down the generator.
  2. Remove the front panel.
  3. Remove the 7.5 amp fuse from the control panel.
  4. Remove the intake side panel.
  5. Disconnect the white battery charger cable.
  6. Inspect the battery posts and cables for tightness and corrosion.
  7. Tighten and clean as necessary.
  8. For unsealed batteries only: Disconnect the battery completely.
  9. Check the battery fluid level and fill with distilled water only if necessary.
  10. Have an IASD or qualified service technician check the state of charge and condition.
  11. Reconnect the battery cables and battery charger cable.
  12. Reinstall the intake side panel.
  13. Reinstall the 7.5 amp fuse.
  14. Place the controller in AUTO mode.
  15. Complete the Installation Wizard Menu.

Tools required

  • Wrench for battery terminals Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Battery: 12V, Group 26R-540CCA or Group 35AGM-650CCA

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.