Home›Repair guides›Generac›Voltage Regulator Adjustment (Units with 15 Inch Stator)

Generac 9344 — Voltage Regulator Adjustment (Units with 15 Inch Stator)

Adjustments · AC voltage regulator Part No. 67680

For the Generac 9344, from the Generac service manual.

Applies to: Generac 9344

Before you start

  • Do not force the regulator's adjustment potentiometer past its stops.

Procedure

  1. Gain access to the voltage regulator in the generator control panel.
  2. If a new regulator is installed, set switch SW1 to Position 2.
  3. With unit shut down, turn Voltage Adjust pot fully counterclockwise; set Gain and Stability to mid-position.
  4. Do not adjust the Underfrequency Adjust pot.
  5. Start the engine and let it stabilize and warm up at no-load; verify frequency 60.5-63.5 Hertz.
  6. Turn the Voltage Adjust pot to obtain 242-254 volts line-to-line or 121-127 volts line-to-neutral.
  7. If the Regulator lamp flashes, turn the Stability pot until flashing stops.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Line-to-neutral voltage 121-127 volts AC
  • Line-to-line voltage 242-254 volts AC

Full service-parts list: Generac 9344 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.