Home›Repair guides›Generac›Testing Stator Insulation to Ground

Generac 91401256S / Bsc 556 — Testing Stator Insulation to Ground

Testing & diagnosis · stator windings

For the Generac 91401256S / Bsc 556, from the Generac service manual.

Browse Generac generators & specs →

Before you start

  • Connect tester probes only to stator leads. Do not connect to control console leads.

Procedure

  1. Disconnect and isolate all stator output leads in AC connection panel.
  2. Connect terminal ends of all stator output leads together.
  3. Ensure none of the lead terminal ends contact the generator frame.
  4. Connect red hi-pot test probe to joined stator lead terminal ends.
  5. Connect black tester probe to clean frame ground on stator can.
  6. Turn hi-pot tester switch off, set voltage selector to 500 volts.
  7. Turn tester on and check pilot lamp.
  8. Observe breakdown lamp, wait one second, then turn tester off.
  9. If breakdown lamp illuminates, clean and dry stator and repeat test.
  10. If breakdown occurs again after cleaning and drying, replace stator assembly.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 500 volts
  • one second maximum

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.