Home›Repair guides›Generac›Testing Rotor Insulation on Direct Excited Units

Generac 91401256S / Bsc 556 — Testing Rotor Insulation on Direct Excited Units

Testing & diagnosis · rotor assembly

For the Generac 91401256S / Bsc 556, from the Generac service manual.

Browse Generac generators & specs →

Procedure

  1. Gain access to rotor brushes and slip rings.
  2. Disconnect all wires from brushes or remove brush holders.
  3. Connect red hi-pot tester probe to positive slip ring nearest rotor bearing.
  4. Connect black tester probe to clean frame ground.
  5. Turn hi-pot tester switch off, plug into 120 VAC outlet.
  6. Set voltage selector to 500 volts, turn tester on and check pilot lamp.
  7. Set voltage selector to 1250 volts and observe breakdown lamp, then turn tester off.
  8. If breakdown lamp comes on, drying may be necessary; after cleaning and drying repeat test.
  9. If rotor fails second test, replace it.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 500 volts
  • 1250 volts
  • one second maximum

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.