Generac 2.4 L / 60kW 1.5L — Remove From Service
Maintenance · Generator
For the Generac 2.4 L / 60kW 1.5L, from the Generac owner's manual.
Applies to: Generac 2.4 L, Generac 2.4L engine, Generac 1.5L engine
Before you start
- If unit has been running, wait five minutes for engine to cool
Procedure
- Open viewing window.
- Move Main Circuit Breaker switch down to OFF (Open) position.
- Verify both auxiliary shutdown switches are OFF (O).
- Press OFF on control panel.
- Remove T1 fuse from transfer switch.
- Pull up rubber flap covering fuse holder and remove 7.5 amp fuse.
- Disconnect NEGATIVE battery cable.
- Place a DO NOT OPERATE tag on control panel and transfer switch.
Specs & values
- 7.5 amp fuse
Full service-parts list: Generac 2.4 L →