Procedure
- 4.3.3 OIL & OIL FILTER CHANGE PROCEDURE To change the oil, proceed as follows:
- 1. Start the engine by moving the AUTO/OFF/MANUAL switch to MANUAL and run until it is thoroughly warmed up. Then shut OFF the engine by moving the switch to the OFF position.
- 2. Immediately after the engine shuts OFF, pull the oil drain hose (Figure 4.1) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container.
- 3. After the oil has drained, replace the cap onto the end of the oil drain hose. Retain the hose in the clip. Change the engine oil filter as follows:
- 1. With the oil drained, remove the old oil filter by turning it counterclockwise.
- 2. Apply a light coating of clean engine oil to the gasket of the new filter. See the Specifications section for recommended filter.
- 3. Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter. Then, tighten the filter an additional 3/4 to one turn (Figure 3.4).
- 4. Refill with the proper recommended oil (see the Engine Oil Recommendations section). See the Specifications section for oil capacities.
- 5. Start the engine, run for one (1) minute, and check for leaks.
- 6. Shutdown and recheck oil level, add as needed. DO NOT OVER FILL.
Source: manual:696471058185_use.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.