Generac 006000-0 — Long Term Storage
Maintenance · Generator
For the Generac 006000-0, from the Generac owner's manual.
Browse Generac generators & specs →
Before you start
- Allow unit to cool entirely before storage.
- Avoid spray from spark plug hole when cranking engine.
- Never cover the generator while engine and exhaust area are warm.
Procedure
- While engine is still warm, drain oil from crankcase and refill with recommended grade.
- Remove spark plug and pour about 1/2 ounce (15 ml) of engine oil into the cylinder.
- Cover spark plug hole with rag and pull recoil starter a couple times to lubricate piston rings and cylinder bore.
- Install and tighten spark plug; do not connect spark plug wire.
- Clean generator outer surfaces and check cooling air slots are open and unobstructed.
- Store the unit in a clean, dry place.
- If possible store indoors and cover; be sure to close the valve on the fuel tank.
Specs & values
- Start generator at least once every seven days and run at least 30 minutes
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.