Generac 006000-0 — Long Term Storage

Maintenance · Generator

For the Generac 006000-0, from the Generac owner's manual.

Browse Generac generators & specs →

Before you start

  • Allow unit to cool entirely before storage.
  • Avoid spray from spark plug hole when cranking engine.
  • Never cover the generator while engine and exhaust area are warm.

Procedure

  1. While engine is still warm, drain oil from crankcase and refill with recommended grade.
  2. Remove spark plug and pour about 1/2 ounce (15 ml) of engine oil into the cylinder.
  3. Cover spark plug hole with rag and pull recoil starter a couple times to lubricate piston rings and cylinder bore.
  4. Install and tighten spark plug; do not connect spark plug wire.
  5. Clean generator outer surfaces and check cooling air slots are open and unobstructed.
  6. Store the unit in a clean, dry place.
  7. If possible store indoors and cover; be sure to close the valve on the fuel tank.

Specs & values

  • Start generator at least once every seven days and run at least 30 minutes

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.