Generac 006000-0 — Connecting LP Fuel Tank

Installation

For the Generac 006000-0, from the Generac owner's manual.

Browse Generac generators & specs →

Before you start

  • Do not use or store LP cylinder in a building, garage or enclosed area except as authorized by NFPA 58 or B149.2.
  • Do not check for leaks with a match or flame.
  • The cylinder valve should be left off (closed) when the generator is not in use.
  • Contact with liquid contents of the cylinder will cause freeze burns to the skin.

Procedure

  1. Use only standard 20 pound capacity LP tanks with Type 1, right hand Acme threads.
  2. Lift the tank and place in rear tank bracket and tank shroud with connection point facing front.
  3. Remove the safety plug or cap from the cylinder valve.
  4. Attach the connector snugly into the valve (turn plastic coupling right/clockwise to tighten).
  5. Position cylinder so valve-to-regulator connection does not cause sharp bends or kinks.
  6. Check for leaks by spraying soapy water on the connections being tested.
  7. If bubbles appear, grow larger or increase in number, a leak exists; correct before using.

Specs & values

  • Regulator inlet pressure range from LP tank: 30 to 100 psi

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.