Procedure
- Remove the generator from engine as described in Generator Removal section.
- Remove the four screws (T20 Torx type head) attaching the voltage regulator to the generator housing. Remove the voltage regulator with generator brush holder (10351) attached, from the generator.
Tools required
- T20 Torx type head screwdriver
Specs & torque values
- Screw torque: 2.3-3.4 Nm (20-30 In-Lb)
Source: manual:WSG1068 Sec. 06 Charging.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.