Before you start

  • Voltage limiter calibration tests must be made with battery and ignition loads only

Procedure

  1. Make connections to battery and tester as shown (Voltage Limiter Test).
  2. Place transmission in neutral/park and apply parking brake.
  3. Close battery adapter switch and start engine with all lights/accessories off; open adapter switch.
  4. Operate engine at approximately 2000 rpm for 5 minutes using a tachometer.
  5. Read the voltmeter; if within specification the regulator and alternator are functioning normally.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Battery specific gravity must be at least 1.230 before accurate testing

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.