Ford ES — TESTING OUTPUT BRIDGE DIODES
For the Ford ES.
Browse Ford generators & specs →
Procedure
- Connect one ohmmeter lead to each end of diode
- Reverse ohmmeter leads and again observe re-
- Replace defective diodes with new, identical
- Wires 1-2 and 3-4 are wound on thesame iron core.
Specs & torque values
- printed circuit board. Using an accurate ohmmeter,
- 1. Connect one ohmmeter lead to each end of diode
- 2. Reverse ohmmeter leads and again observe re-
- OHMMETER
- Using a 6 volt dry cell battery and a 200 ohm
- nect a DC voltmeter across the 200 ohm resistor.
- 0.39 ohms and 0.38 to 0.46 ohms respectively at 77" F
- ohms, between Xl-X2 133 to 163 ohms at 77OF
- between field leads should be 10.98 to 13.42 ohms at
- OHMMETER RESISTANCE BETWEEN
- 10.98 TO 13.42 OHMS
- Connect ohmmeter between either field lead and
- exciter stator laminations. Use ohmmeter set at
- R x 100 scale. An ohmmeter reading of less than
- OHMMETER