Home›Repair guides›Ford›Starter Motor Installation

Ford — Starter Motor Installation

Installation

From a Ford service manual — check it applies to your exact model before use.

Browse Ford generators & specs →

Procedure

  1. Position starter motor to engine and install upper and lower bolt finger-tight.
  2. Tighten the upper bolt to 21-27 N-m (15-20 ft-lb). Access to upper bolt is with a 3/8 inch drive ratchet, swivel socket and a 22 inch long extension.
  3. Tighten the lower bolt to 21-27 N-m (15-20 ft-lb).
  4. Connect starter solenoid connector. Push straight on and make sure connector locks in position with a notable click or detent.
  5. Install starter cable nut to starter terminal. Tighten to 9-13 N-m (80-120 in-lb).
  6. Replace red solenoid safety cap.
  7. Connect negative battery ground cable.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.