Home›Repair guides›Ford›Racine Proportional Air Gap Adjustment

Ford — Racine Proportional Air Gap Adjustment

Adjustments · Racine proportional valve

From a Ford service manual — check it applies to your exact model before use.

Browse Ford generators & specs →

Before you start

  • All parts must be clean and properly assembled before making these checks.

Procedure

  1. With all parts assembled, use a depth mike to measure distance from end of guide tube to exposed end of plunger; record dimension.
  2. Remove plunger and poppet; install plunger and check distance from end of guide tube to exposed end of plunger.
  3. Subtract the first dimension from the second; this is the amount of air gap.
  4. Correct air gap is .018"-.020" with .018" preferred.
  5. If excessive, lightly tap end of plunger with a brass drift and hammer; recheck air gap.
  6. If air gap is less than recommended, replace nose cone assembly.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • .018"-.020" air gap
  • .018" preferred

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.