Ford — Pinpoint Test B - Starter Does Not Crank
Testing & diagnosis · Starting system
From a Ford service manual — check it applies to your exact model before use.
Browse Ford generators & specs →
Procedure
- Turn and hold the Ignition switch in the START position. Using an ohmmeter, measure for battery voltage at the starter solenoid START terminal.
- Disconnect the starter lockout relay. Turn and hold the Ignition switch in the START position. Measure for battery voltage on Circuit 32A RD/LB at the starter lockout relay connector.
- Key OFF. Measure resistance between Circuit 32 RD/LB at the starter lockout relay connector and the starter solenoid ignition start terminal.
- Disconnect the starter lockout relay. KOEO. Turn and hold the Ignition switch in the START position. Measure resistance between Circuit 113 YL/LB and known good ground.
- Key Off. Disconnect the starter lockout relay. Measure resistance between the Starter Lockout Relay terminals 30 and 87A.
- Key OFF. Disconnect the ICM connector C4 and the starter lockout relay. Measure resistance between Circuit 113 YL/LB at the starter lockout relay connector and known good ground.
Tools required
- Ohmmeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Battery Voltage
- less than 5 Ohms
- greater than 5 Ohms
Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.