From a Ford service manual covering: MP 110, MP 95, MPH 80. Check it applies to your exact model before use.
Browse Ford generators & specs →
Procedure
- Locate the pressure compensator adjusting screw on the load sensing housing on the control valve section of the pump assembly.
- Loosen the locknut and turn screw in to increase system pressure or out to decrease system pressure.
- Set system pressure at the prescribed setting (see Machine Specifications).
Specs & values
- System pressure should be set at a predescribed setting (see Machine Specifications).
Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.