Home›Repair guides›Ford›Governor No-Load Surge Adjustment

Ford — Governor No-Load Surge Adjustment

Adjustments · Mechanical governor

From a Ford service manual — check it applies to your exact model before use.

Browse Ford generators & specs →

Before you start

  • Do not turn the screw in all the way - it will interfere with proper governor operation

Procedure

  1. With engine under no load at maximum governed speed, loosen the locknuts.
  2. Adjust screw to move the spring towards the lever hub.
  3. Tighten the locknuts.
  4. Recheck governor operation under load and no-load conditions.
  5. Readjust the governor high-speed stop screw to maintain correct high-speed under load.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.