Home›Repair guides›Ford›Fuel Pump Capacity (Volume) Test

Ford — Fuel Pump Capacity (Volume) Test

Testing & diagnosis

From a Ford service manual covering: 140 CID, 2.3 LITRE, 2300 cc, LSG-423. Check it applies to your exact model before use.

Browse Ford generators & specs →

Procedure

  1. Operate engine at specified idle rpm.
  2. Open hose restrictor and expel fuel into container while observing time required to expel one pint.
  3. Close restrictor.
  4. One pint or more of fuel should be expelled within the specified time limit.
  5. If volume is below specification, repeat test using auxiliary fuel supply and a new fuel filter.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Minimum volume flow: 1 pint in 25 seconds

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.