Ford — Drive Controller Lo Threshold (Deadband) and Hi Threshold (Max. Output) Adjustment
Adjustments
From a Ford service manual covering: MP 110, MP 95, MPH 80. Check it applies to your exact model before use.
Browse Ford generators & specs →
Before you start
- If turned too high, full flow will occur at a lesser control angle and some controllability will be lost.
Procedure
- Turn appropriate Lo Threshold (Deadband) potentiometer fully counterclockwise.
- Push control lever forward until a proximity switch inside the control lever clicks.
- Turn the Lo Threshold (Deadband) potentiometer clockwise to permit initial flow (first movement).
- Push control lever fully forward.
- Turn the Hi Threshold (Max. Output) potentiometer to just permit maximum flow.
Specs & values
- If turned too high, full flow will occur at a lesser control angle and some controllability will be lost.
Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.