Ford — CO Aat BOS 28001
A Ford service procedure — check it applies to your exact model before use.
Browse Ford generators & specs →
Procedure
- Secure one end of wire ropes in place on tip boom (fourth stage) with extend rope anchor. Also, secure the retract wire rope in place with return cable anchor.
- With tip boom base-end wear pads in place, slide tip boom and wire ropes into outer mid boom (third stage).
- Slide tip boom into outer mid boom (third stage); then, install rear wear pads onto outer mid boom (third stage). To install bottom wear pads, lift tip boom.
- With wire ropes attached, slide telescope cylin- der into outer mid boom (third stage). Install retract rope guides and extend/ retract cable anchor along with wire ropes.
- While supporting telescope cylinder, install outer mid boom (third stage).
- Slide oufer mid boom (third stage) and wire ropes into inner mid boom (second stage) far enough to hook up the two extend wire ropes; then pull outer mid boom (third stage) and tip boom (fourth stage) back out enough to access sheaves.
- Install wear pads onto rear of inner mid boom (second stage). To install bottom rear wear pads, lift outer mid boom third stage).
Source: manual:89-103317.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.