HomeRepair guidesGenerator Installation on Engine

Ford — Generator Installation on Engine

A Ford service procedure — check it applies to your exact model before use.

Browse Ford generators & specs →

Procedure

  1. Position the generator on the generator bracket.
  2. Install the bolts and tighten to 40-55 Nm (30-40 ft-lb).
  3. Install the drive belt over the generator pulley.
  4. Relieve the tension of the drive belt tensioner and install the drive belt over tensioner.
  5. Connect generator voltage regulator wiring to the voltage regulator. Tighten generator Battery Positive Voltage (B+) wire attaching nut to 9-12 Nm (6.5-9 ft-lb).
  6. Install wiring connector bracket.
  7. Install snow/ice shield.
  8. Connect battery ground cable.

Specs & torque values

  • Mounting bolt torque: 40-55 Nm (30-40 ft-lb)
  • Battery Positive Voltage (B+) wire nut torque: 9-12 Nm (6.5-9 ft-lb)

Source: manual:WSG1068 Sec. 06 Charging.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.