Home›Repair guides›Ford›Adjusting the Choke Pull-Off

Ford — Adjusting the Choke Pull-Off

Adjustments · Carburetor automatic choke

From a Ford service manual — check it applies to your exact model before use.

Browse Ford generators & specs →

Procedure

  1. Remove the choke housing cover.
  2. Remove the cork insulation strip.
  3. Remove the inner plate.
  4. Position the sliding pin in the slip link slot away from the piston.
  5. Place a 9.52 mm (0.375 inch) gage pin between the top of the choke plate and the inside of the air intake.
  6. Adjust the stop screw until the slip link starts to move away from the pin.
  7. Tighten the lock nut to 0.9-1.4 Nm (8-12 lb. in.).
  8. Install the inner plate, cork insulation strip and choke housing cover.

Tools required

  • 9.52 mm (0.375 inch) gage pin Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Choke opening 9.52 mm (0.375 inch)
  • Lock nut 0.9-1.4 Nm (8-12 lb. in.)

Source: Ford service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.