Home›Repair guides›Ford›Lines With a Bypass

Ford 80 Series / 84A2-F140 — Lines With a Bypass

Operation · Bypass line

For the Ford 80 Series / 84A2-F140, from the Ford owner's manual.

Browse Ford generators & specs →

Procedure

  1. If a Gorman-Rupp automatic air release valve is installed, close the throttling valve in the discharge line.
  2. The Gorman-Rupp valve automatically opens to allow the pump to prime and closes when priming is accomplished.
  3. After the pump is primed and liquid flows steadily from the bypass line, open the discharge throttling valve.
  4. If a hand operated shutoff valve is installed, close the discharge throttling valve and open the bypass shutoff valve.
  5. When primed and liquid flows steadily from the bypass line, close the bypass shutoff valve and open the discharge throttling valve.

Source: Ford owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Ford repair guides →