Before you start

  • Never open vent screw while generator is running.

Procedure

  1. Switch off generator.
  2. Ensure external expansion tank connected and mounted at sufficient height.
  3. Open ventilating screw above cooling water pump casing.
  4. Open ventilating screw on thermostat casing.
  5. Pour cooling water into filling necks.
  6. When level stops dropping, close filler cover and vent screws.
  7. Start generator, run approx. 60 seconds, then switch off.
  8. Refill cooling water via compensation tank.
  9. Repeat procedure 1-5 times until no air remains.

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.