Fischer Panda — Ventilating at the first filling of the Internal Cooling Water Circuit
Installation · cooling system
From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Before you start
- Never open vent screw while generator is running.
Procedure
- Fill external cooling water expansion tank with coolant; max mark.
- Open vent screw on pipe socket of internal cooling water pump; close when air-free water comes out.
- Open vent screw on thermostat housing; close when air-free water comes out.
- Start generator and run without load; switch off after about 10 seconds.
- Repeat steps 1-4 until no air comes out; close vent screws; fill expansion tank; close tank.
- Re-ventilate after 10 operating hours.
Specs & values
- Maximum fill level = max mark
- Re-ventilate after 10 operating hours
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.