Home›Repair guides›Fischer Panda›Stopping the generator

Fischer Panda — Stopping the generator

Operation

From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.

Browse Fischer Panda generators & specs →

Before you start

  • Never switch off battery until generator has stopped.

Procedure

  1. Switch off load.
  2. For turbo engines or load >70% rated, stabilize at least 5 minutes with load off.
  3. At ambient >25°C, run at least 5 minutes without load before stopping.
  4. Press button OFF; LED on off.
  5. Never switch off battery until generator has stopped; close fuel valve if necessary.

Specs & values

  • Stabilize at least 5 minutes with load off for turbo engines or >70% load

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →