Fischer Panda — Stopping the generator
Operation
From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Before you start
- Never switch off battery until generator has stopped.
Procedure
- Switch off load.
- For turbo engines or load >70% rated, stabilize at least 5 minutes with load off.
- At ambient >25°C, run at least 5 minutes without load before stopping.
- Press button OFF; LED on off.
- Never switch off battery until generator has stopped; close fuel valve if necessary.
Specs & values
- Stabilize at least 5 minutes with load off for turbo engines or >70% load