Fischer Panda — Starting the generator
Operation
From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Before you start
- In event of starting problems, close sea water inlet cock to avoid flooding exhaust.
Procedure
- Press button ON; LED on green.
- Press button HEAT; LED heat orange. Pre-heat necessary below 20°C.
- Press button START; LED start green. Starter max 20 seconds, then pause at least 60 seconds.
- Switch on load only after voltage is within permissible range.
- If starting problems, close sea water inlet cock (marine generators only); open once running.
Specs & values
- Pre-heat necessary at operating temperature <20°C
- Starter max 20 seconds, pause at least 60 seconds
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.