Fischer Panda — Setting the normal speed settings
Adjustments · actuator
From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Procedure
- Remove plug from electrical input.
- Loosen counter nuts against each other with two SW 10 spanners.
- Connect voltmeter up to 300 V AC to AC Control Box output.
- Ensure no electrical load.
- Start generator.
- Turn servomotor spindle downwards by hand until voltmeter shows 225 V (110 V).
- Tighten both nuts tightly against each other.
- Recheck lower voltage limit is 225 V (110 V).
- Tighten counter nuts at max 260 V (130 V).
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Lower voltage setting: 225 V (110 V)
- Upper voltage setting: 260 V (130 V)