Fischer Panda — Setting the maximum upper speed setting
Adjustments · actuator
From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Before you start
- This setting should not be changed otherwise the guaranty will expire.
Procedure
- Remove plug from electrical input for actuator.
- Loosen counter nuts of speed governor screws with SW 10.
- Connect voltmeter up to 300 V AC to AC output of AC Control Box.
- Ensure no electrical load.
- Start generator.
- Raise speed by turning spindle of servomotor until voltmeter reaches 260 V (130 V).
- Turn governor screw firmly against stop of speed adjustment lever.
- Secure governing screw with counter nut.
- Recheck voltage is 260 V (130 V).
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Upper voltage setting: 260 V (130 V)
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.