Home›Repair guides›Fischer Panda›Pressure test cooling circuit

Fischer Panda 12mini / Panda 12 mini PMS Digital — Pressure test cooling circuit

Testing & diagnosis

For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda service manual.

Applies to: Fischer Panda MINI, Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine

Procedure

  1. Feel cooling water in-flow line at internal cooling water pump.
  2. Feel cooling water return pipe at exhaust elbow outlet or heat exchanger inlet.
  3. Temperature difference between in-flow and return should be approx 10 degrees.

Specs & values

  • Approx 10 degrees

Full service-parts list: Fischer Panda MINI →, Fischer Panda Panda 12 mini PMS Digital →, Kubota D722 engine →

Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.