Home›Repair guides›Fischer Panda›Filling and de-aerating of the internal cooling water circuit

Fischer Panda 12mini / Panda 12 mini PMS Digital — Filling and de-aerating of the internal cooling water circuit

Installation · Cooling system

For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine

Before you start

  • Do not open ventilation screw above cooling water pump while generator is running.

Procedure

  1. Fill external expansion tank with coolant to max mark; open cap.
  2. Start generator; do not load; switch off after max 2 minutes.
  3. Wait about one minute for air to rise.
  4. Open all three ventilation points one after another until cooling water exits; close screws.
  5. Repeat de-aeration steps until no air exits.
  6. Check cooling water is circulating.

Specs & values

  • Coolant/antifreeze mixture good for at least -15°C (5°F)

Full service-parts list: Fischer Panda Panda 12 mini PMS Digital →, Kubota D722 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →