Home›Repair guides›Fischer Panda›Fill and de-aerate internal cooling circuit

Fischer Panda 12mini / Panda 12 mini PMS Digital — Fill and de-aerate internal cooling circuit

Installation · freshwater cooling circuit

For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda service manual.

Applies to: Fischer Panda MINI, Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine

Before you start

  • During de-aeration check coolant is circulating; overheating possible if air bubbles remain.

Procedure

  1. Open cooling water cap on water-cooled exhaust elbow union.
  2. Open de-aerating screw on thermostat housing.
  3. Open de-aerating screw on internal cooling water pump pipe socket.
  4. Fill prepared coolant mixture slowly at filler neck until coolant leaks at thermostat housing de-aerating screw.
  5. Screw cooling water cap firmly and close both de-aerating screws.
  6. Fill external expansion tank to max mark.
  7. Start generator and run max 2 minutes without load.
  8. Stop generator and wait about 1 minute for air to rise.
  9. Open all three ventilation points until cooling water exits; close immediately.
  10. Repeat de-aeration until no air exits.
  11. Repeat de-aeration during next few days.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • External expansion tank max fill level = max mark

Full service-parts list: Fischer Panda MINI →, Fischer Panda Panda 12 mini PMS Digital →, Kubota D722 engine →