Home›Repair guides›Fischer Panda›Exchange impeller

Fischer Panda 12mini / Panda 12 mini PMS Digital — Exchange impeller

Maintenance · raw water pump

For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda service manual.

Applies to: Fischer Panda MINI, Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine

Procedure

  1. Close raw water stop cock.
  2. Remove cover of raw water pump by loosening screws.
  3. Pull impeller from shaft with multigrip pliers.
  4. Mark impeller position before removal.
  5. Check impeller for damage and replace if necessary.
  6. Lubricate impeller with glycerin or non-mineral oil based lubricant.
  7. Install impeller on pump shaft in marked position.
  8. Fasten cover with new seal.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Replace every few months; if raw water does not appear within 5 seconds after start.

Full service-parts list: Fischer Panda MINI →, Fischer Panda Panda 12 mini PMS Digital →, Kubota D722 engine →

Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →