Fischer Panda 12mini / Panda 12 mini PMS Digital — De-aerate coolant circuit

Maintenance · freshwater cooling circuit

For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda service manual.

Applies to: Fischer Panda MINI, Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine

Before you start

  • Do not open cooling water pump de-aerating screw while generator runs.

Procedure

  1. Ensure generator is stagnant.
  2. Check external expansion tank connected and at least 600 mm above exhaust elbow union.
  3. Open de-aerating screw at cooling water pump.
  4. Open de-aerating screw at thermostat housing.
  5. Fill coolant at filler neck until level stops falling.
  6. Close filler cap and de-aerating screws.
  7. Start generator and run 5 minutes.
  8. Repeat de-aeration two to three times.
  9. Refill external expansion tank only to max 20% cold.
  10. Repeat after several days.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • External expansion tank at least 600 mm above exhaust elbow union
  • Refill cold to max 20%