Fischer Panda 12mini / Panda 12 mini PMS Digital — Bleeding fuel system
Maintenance
For the Fischer Panda 12mini / Panda 12 mini PMS Digital, from the Fischer Panda service manual.
Applies to: Fischer Panda MINI, Fischer Panda Panda 12 mini PMS Digital, Kubota D722 engine
Before you start
- Avoid fuel spill in sound cover.
Procedure
- Switch Stand by switch ON.
- Push and hold failure bypass switch (or fuel pump switch S3).
- Run electric fuel pump audibly 3 to 4 minutes.
- Unscrew bleeding screw of fuel solenoid valve while holding switch.
- Place cloth under connection to catch fuel.
- Close bleeding screw when fuel runs without bubbles.
- Release switch.
- Start unit with Run/Stop button.
- If unit does not start, loosen pipe union nuts at injection nozzles and retry.
- Tighten pipe union nuts after start.
- Switch Stand by OFF.
Tools required
- Spanner Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Fischer Panda MINI →, Fischer Panda Panda 12 mini PMS Digital →, Kubota D722 engine →
Source: Fischer Panda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.