Firman WH03662OF — Starting the Generator on LPG

Operation · Engine

For the Firman WH03662OF, from the Firman operator's manual.

Browse Firman generators & specs →

Before you start

  • Observing frost on LPG cylinder/regulator is common and normally not a problem

Procedure

  1. Check for loose/missing parts and shipping damage
  2. Move generator outdoors, at least 20 ft (6 m) from occupied spaces
  3. Connect LPG hose with regulator to LPG cylinder and generator inlet
  4. Fully open the LPG cylinder knob
  5. Disconnect all electrical loads from the generator
  6. Turn main fuel selector switch to LPG position
  7. Pull choke knob to START position
  8. For recoil start, pull-to-prime the starter cord 1-2 times
  9. Move choke knob to RUN position
  10. Pull starter cord to run the generator, or flip electric start switch to START
  11. Allow generator to run at no load for a few minutes before plugging in devices

Source: Firman operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.