Firman WH03344 — Starting the Generator on LPG

Operation · Engine

For the Firman WH03344, from the Firman manual.

Browse Firman generators & specs →

Before you start

  • LPG is extremely flammable.
  • Keep fire extinguisher nearby.
  • Check connections for leaks daily.

Procedure

  1. Check for loose or missing parts and any damage.
  2. Move generator outdoors to safe location at least 20 feet from occupied spaces.
  3. Connect LPG hose with regulator to cylinder and generator inlet.
  4. Fully open LPG cylinder knob.
  5. Disconnect all electrical loads.
  6. Turn fuel selector switch to LPG position.
  7. Flip engine switch to RUN position.
  8. Push battery power restore switch for 3 seconds.
  9. Pull choke knob to START position.
  10. Pull starter cord to prime.
  11. Move choke to RUN position.
  12. Allow generator to run and stabilize.

Source: Firman manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.