Firman T04073 — Battery Replacement
Repair & overhaul
For the Firman T04073, from the Firman owner's manual.
Applies to: Firman T04073
Procedure
- Remove spark plug boot from spark plug
- Remove nut and bolt from negative post first, then positive post
- Loosen and remove cap screws and nuts on battery holding bracket
- Remove battery and recycle
- Install new battery: 12V sealed lead acid 7.5AH, 151x65x97mm
- Connect red positive battery cable to battery first
- Connect black negative battery cable to battery second
- Cover posts with boots provided
- Install spark plug boot onto spark plug
Specs & values
- {'item': 'battery', 'value': '12V sealed lead acid 7.5AH'}
Full service-parts list: Firman T04073 →
Source: Firman owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.