HomeRepair guidesProcedure 12

MP-5667 — Procedure 12

For the MP-5667.

Procedure

  1. 1. Install the coil in the contactor base.
  2. 2. Reconnect wire harness leads to coil and tighten
  3. screws.
  4. 3. Install contact assembly on contactor base and
  5. tighten screws.
  6. 4. Reconnect wire harness leads to auxiliary switch.
  7. 5. Reconnect leads between load terminals of the two
  8. contactors.
  9. 6. Reconnect load and power source leads to
  10. contactor terminals.
  11. Component Removal and
  12. Installation—145-400 Amp
  13. Contactors
  14. Mechanical Interlock Removal

Source: manual:mp5667.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.