MP-5667 — Figure 6-14. Mechanical Interlock Installation
For the MP-5667.
Before you start
- NOTE
Procedure
- 2. Install washer and capscrew. Torque capscrew to
- 40 in. lbs. (4.5 Nm).
- 3. Install previously removed contactor on contactor
- assembly panel. See Contactor Installation,
- steps 4 through 8, earlier in this section.
- NOTE
- Use
- L-wrench
- or
- manual
- operator
- to
- align
- mechanical interlocks on the two contactors during
- contactor installation.
- Auxiliary Switch Removal
- 1. Disconnect wiring harness from auxiliary switch.
- 2. Lift mounting tab. See Figure 6-15.
- 5667626
- 1
Tools required
- L-wrench
Specs & torque values
- 4.5 Nm