Eilers.Com.Ar R200X — Seawater Pump Impeller Inspection and Replacement
For the Eilers.Com.Ar R200X.
Browse Eilers.Com.Ar generators & specs →
Before you start
- DO NOT RUN THE ENGINE WITHOUT SEAWATER. THE SEAWATER PUMP IMPELLER WILL BE DAMAGED.
- IMPELLER DAMAGE MAY OCCUR IF APPROPRIATE TOOLS ARE NOT USED WHEN REMOVING THE IMPELLER.
- MAKE SURE TO CHECK O-RING CONDITION AFTER SEAWATER PUMP REASSEMBLY.
- IF THE SEAWATER STRAINER IS NOT PROPERLY ASSEMBLED, AIR CAN BE SUCKED INTO THE COOLING CIRCUIT, DISTURBING THE VACUUM PROCESS.
Procedure
- Stop the engine and close the water valve.
- Remove the impeller housing cover.
- Remove the impeller from inside the seawater pump.
- Check the condition of impeller and bushing.
- Apply soapy water to impeller when assembling, and reassemble towards rotation direction.
- Replace the O-ring on the impeller housing cover.
- Open the water valve.
- Start the engine and check if there is water leakage.
Tools required
- Appropriate tools for impeller removal
Source: manual:INSTALLATIONOPERATION-SERIES-R200.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.