HomeRepair guidesControl Lever Cable Installation and Adjustment

Eilers.Com.Ar R200X — Control Lever Cable Installation and Adjustment

For the Eilers.Com.Ar R200X.

Browse Eilers.Com.Ar generators & specs →

Before you start

  • YOU SHOULD PERFORM ABOVE PROCEDURES AFTER CONTROL LEVER INSTALLATION WHEN ENGINE IS NOT RUNNING BUT IGNITION KEY IS ON.

Procedure

  1. Ensure the acceleration sensor lever is fully released to the idle position and fully pulled to the full-load position.
  2. Idle position setting: Make sure that the position value (%) indicates 0% at neutral condition.
  3. Full load position setting: Make sure that the position value (%) indicates full load range (90~99.2%) at fully forward lever condition. If not, adjust sleeve of control cable.

Specs & torque values

  • Swing distance between idle and full-load position: 60 mm
  • Idle position: 0%
  • Full load position: 90-99.2%

Source: manual:INSTALLATIONOPERATION-SERIES-R200.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.