DuroMax XP5500HX — Emptying the Gas Tank
Maintenance · Fuel system
For the DuroMax XP5500HX, from the DuroMax owner's manual.
Browse DuroMax generators & specs →
Before you start
- Do not store fuel from one season to another
Procedure
- Turn the fuel valve to OFF
- Remove the outward angled bolt located on the bottom of the carburetor
- Place funnel with container to catch gasoline under the drain port location
- Turn the fuel valve to ON and allow gasoline to drain until the tank is empty
- Move the fuel valve back to OFF
- Reinstall the carburetor drain bolt
- Store the emptied gasoline in a suitable place and add fuel stabilizer
Tools required
- funnel Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.