Home›Repair guides›DuroMax›Starting the Generator Using Propane

DuroMax XP5500EH — Starting the Generator Using Propane

Operation · Engine

For the DuroMax XP5500EH, from the DuroMax owner's manual.

Browse DuroMax generators & specs →

Before you start

  • Make sure there is no possible ignition source close to the generator when using LPG

Procedure

  1. Turn breaker OFF
  2. Turn gas valve OFF (rotate clockwise to horizontal)
  3. Connect propane hose to inlet
  4. Screw ACME nut connection to propane tank and turn tank on
  5. Close choke
  6. Press engine switch to START, allow return to RUN
  7. Open choke as engine warms up
  8. Turn breaker ON and connect loads, largest first

Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More DuroMax repair guides →