Procedure

  1. Remove the 2 bolts of the generator cover then pull the cover off
  2. Remove the bolt holding the carbon brush
  3. Remove the two wires from the AVR on the carbon brush
  4. Install new carbon brush with bolt
  5. Insert and connect the 2 wires from the AVR, connecting + and - correctly
  6. Replace the back cover of the generator and secure with 2 bolts

Specs & values

  • Inspect every 250 running hours