DuroMax XP10000HX — Changing/Inspecting the Carbon Brushes
Repair & overhaul · alternator
For the DuroMax XP10000HX, from the DuroMax owner's manual.
Browse DuroMax generators & specs →
Before you start
- Inspect every 250 running hours
Procedure
- Remove the 2 bolts of the generator cover, pull cover off
- Remove the bolt holding the carbon brush
- Remove the two wires from the AVR on the carbon brush
- Install new carbon brush with bolt
- Connect the 2 wires from the AVR, observing polarity
- Replace the back cover with the 2 bolts
Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.