Before you start
- AVR may be damaged by overheating or overloading
Procedure
- Remove the 2 bolts of the generator cover, pull cover off
- Remove the 2 bolts holding the AVR
- Disconnect the wire clip
- Remove the 2 wires from the AVR on the carbon brush
- Install the new AVR with the 2 bolts
- Reconnect the 2 wires to the brush, observing polarity
- Reconnect the AVR wire clip
- Replace the back cover with the 2 bolts