Home›Repair guides›DuroMax›Adding Oil

DuroMax XP10000HX — Adding Oil

Maintenance · engine

For the DuroMax XP10000HX, from the DuroMax owner's manual.

Browse DuroMax generators & specs →

Before you start

  • Do not overfill the crankcase

Procedure

  1. Make sure generator is on a level surface
  2. Unscrew the oil filler/dipstick cap
  3. Using a funnel, add oil until level reaches lower lip of the fill opening
  4. Replace the oil filler cap

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Oil capacity 37.2 fl. oz (1.1L)

Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.